Performance:
• Double conversion online design, output zero conversion time.
• Adopting DSP digital control, with excellent performance indicators, making the control system more stable and reliable.
• Using active power factor correction technology (PFC), the input power factor is close to 1, which greatly reduces the pollution to the mains grid.
• Ultra-wide input voltage range, the input voltage can be as low as 208V without switching to battery power supply.
• Automatically recognize and adapt to the 50/60Hz power system, can be connected to various fuel generators and can work stably.
• With LCD+LED real-time display, users can intuitively understand the UPS operating status.
• Self-diagnostic function at startup, which can detect the hidden failure of the UPS in time.
• With AC input over-voltage and under-voltage protection, output overload protection, short-circuit protection, temperature protection, battery under-voltage warning protection and battery over-charge protection, etc.
• The efficiency of the whole machine is as high as 94.5%, which reduces the power loss of the UPS and saves the user’s use cost.
• The standard RS232 communication interface and an SNMP card (optional) can be installed to realize the UPS remote monitoring function.
• When there is no utility power, you can directly use the battery to cold start.
• With input phase sequence protection function, the phase sequence cannot be turned on when the phase sequence is reversed.
Specification:
Model | EH9315-20KS | EH9315-30KS | EH9315-40KS |
---|---|---|---|
Rated Capacity | 20KVA/18KW | 30KVA/27KW | 40KVA/32KW |
Input | |||
AC Input Connection Type | 3W+N+PE | ||
Rated Input Voltage | AC 380V/400V/415V | ||
Voltage Range | AC 208V~478V | ||
Frequency Range | 45-55Hz at50Hz/54-66Hz at60Hz (Auto Sensing) | ||
Input Power Factor | ≥0.99 | ||
Input current Harmonics | ≤3% (100% Non-linear Load) | ||
Bypass Range | Bypass protection voltage upper limit: 220V: +25% (optional: +10%, +15%,+25%)
230V: +20% (optional +10%, +15%) 240V: +15% (optional +10%) |
||
Bypass protection voltage lower limit: -45% (optional -20%, -30%) | |||
Bypass bypass protection range: ±10% | |||
Output | |||
AC Output Connection Type | L+N+PE | ||
Output Voltage | 220/230/240VAC | ||
Output Power Factor | 0.8/0.9 | ||
Output Accuracy | ±1% | ||
Output Frequency | Online mode: follow the mains frequency, battery mode: 50/60Hz±0.2% | ||
Output Harmonic Distortion | ≤ 2% linear load; ≤ 5% non-linear load | ||
Battery | |||
Number Of Batteries | Optional: DC±192V/204V/216V/228V/240V (±16/17/18/19/20 pcs)Default: DC±192V | ||
Recharging Current | 10A max | ||
Other | |||
Switching Time | Mains mode to bypass mode: 0ms; Mains mode to battery mode: 0ms | ||
Normal mode (full load) | ≥Efficiency 94.5% | ||
Communication Interface | RS232, RS485, SNMP card (optional), relay card (optional) | ||
Protection | |||
Overload Protection | Load ≤ 110%, 60min; ≤ 125%, 10min; ≤ 150%, 1min; ≥ 150%, immediately transfer to bypass | ||
Over Temperature Protection | Normal mode: switch to bypass mode; battery mode: turn off the output immediately | ||
Emergency Shutdown (EPO) | Turn off output immediately | ||
Maintenance Bypass | Standard maintenance bypass switch | ||
Working Environment | |||
Operating Temperature | 0~40? | ||
Storage Temperature | -25~55? (Battery: 0~40? ) | ||
Relative Humidity | 0%~95% (no condensation) | ||
Altitude | Altitude <1500m, when it exceeds 1500m, use derating according to GB/T 3859.2 | ||
Physics Characteristic | |||
Overall Volume (D*W*H) (mm) | 690*250*734 | ||
Net Weight (kg) | 46 | 47 | 48 |